Renewable Design for Vacuum Contactor Switch - Siemens Type AC Contactor J3TF – JUHONG
Renewable Design for Vacuum Contactor Switch - Siemens Type AC Contactor J3TF – JUHONG Detail:
Type | J3TF-9/12 | J3TF-16/22 | J3TF-32 | J3TF-45/63 | J3TF-75/85 | J3TF-110/140 | J3TF-170/205 | J3TF-250/300 | J3TF-400/475 | |
Mechanical Endurance(X106) |
10 | 10 | 10 | 8 | 8 | 8 | 8 | 8 | 8 | |
Conventional thermal current(A) |
20 | 30 | 45 | 80 | 100 | 160 | 210 | 300 | 400/550 | |
Rated insulation voltage(V) |
660 | 660 | 660 | 1000 | 1000 | 1000 | 1000 | 1000 | 1000 | |
Rated operating current(A) |
AC-3 | 9/12 | 16/22 | 32 | 45/63 | 75/85 | 110/140 | 170/205 | 250/300 | 400/475 |
AC-4 | 3.3/4.3 | 7.7/8.5 | 15.6 | 24/28 | 34/42 | 54/68 | 75/96 | 110/125 | 150 | |
Power of controllablemotor(KW) AC-3 | 380V | 4/5.5 | 7.5/11 | 15 | 22/30 | 37/45 | 55/75 | 90/110 | 132/160 | 200/250 |
660V | 5.5/7.5 | 11 | 23 | 39/55 | 67 | 100 | 156 | 235 | 375 | |
Power of controllablemotor(KW) AC-4 | 380V | 1.4/1.9 | 3.5/4 | 7.5 | 12/14 | 17/21 | 27/35 | 38/50 | 58/66 | 81 |
660V | 2.4/3.3 | 6/6.6 | 13 | 20.8/24 | 29.5/36 | 46.9/60 | 66/86 | 100/114 | 140 | |
Frequency of operation (I/h) |
AC-3 | 1000 | 750 | 750 | 1200/1000 | 1000/850 | 1000/750 | 700/500 | 700/500 | 500/420 |
AC-4 | 250 | 250 | 250 | 400/300 | 300/250 | 300/200 | 200/130 | 200/130 | 150 | |
Electrical endurance (X106) |
AC-3 | 1.2 | 1.2 | 1.2 | 1.2 | 1.2 | 1.2 | 1.2 | 1.2 | 1.2 |
AC-4 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | |
Operating voltage range of coil |
(0.8-1.1)Ue | |||||||||
Power consumption of coil |
Atracting (VA) |
10 | 10 | 12.1 | 17 | 32 | 39 | 58 | 84 | 115 |
Starting (VA) |
68 | 69 | 101 | 183 | 330 | 550 | 910 | 1430 | 2450 | |
Rated insulation voltageof auxiliary contacts(V) | 690 | 690 | 690 | 690 | 690 | 690 | 690 | 690 | 690 | 690 |
Conventional thermal currentof auxiliary contacts(A) | 10 | 10 | 10 | 10 | 10 | 10 | 10 | 10 | 10 | 10 |
Rated operating currentof auxiliary contacts(A) | AC15 380/220 |
6/10 | 6/10 | 4/6 | 4/6 | 4/6 | 4/6 | 4/6 | 4/6 | 4/6 |
DC13 220v |
0.45 | 0.45 | 0.45 | 0.45 | 0.45 | 0.45 | 0.45 | 0.45 | 0.45 | |
Rated voltage of the control coil(V) |
50HZ | 24 36 48 110 127 220 380,etc | ||||||||
60HZ | 24 110 220 440 etc |
Product detail pictures:





Related Product Guide:
We believe in: Innovation is our soul and spirit. Top quality is our life. Purchaser need is our God for Renewable Design for Vacuum Contactor Switch - Siemens Type AC Contactor J3TF – JUHONG , The product will supply to all over the world, such as: Sao Paulo, Pakistan, azerbaijan, You can do one-stop shopping here. And customized orders are acceptable. Real business is to get win-win situation, if possible, we would like to provide more support for customers. Welcome all nice buyers communicate details of products and ideas with us!!

This manufacturer can keep improving and perfecting products and service, it is in line with the rules of market competition, a competitive company.

Write your message here and send it to us