Technical Characteristic

Type Rated current of trip unit In(A) Setting current adjustment range (A) Rated ultimate short-circuit breaking capacity lcu (kA), rated operating short-circuit breaking capacity lcs (kA) Arcing distance (mm)
230/240V 400/415V 440V 500V 690V
Icu Ics Icu Ics

Icu

Ics Icu Ics Icu Ics
0.16

0.1-0.16

100 100 100 100

100

100 100 100 100 100

40

0.25

0.16-0.25

100 100 100 100

100

100 100 100 100 100

40

JGV2-32 0.4

0.25-0.4

100 100 100 100

100

100 100 100 100 100

40

0.63

0.4-0.63

100 100 100 100

100

100 100 100 100 100

40

1 0.63-1 100 100 100 100

100

100 100 100 100 100

40

1.6 1-1.6 100 100 100 100

100

100 100 100 100 100

40

2.5 1.6-2.5 100 100 100 100

100

100 100 100 3 2.25

40

4 2.5-4 100 100 100 100

100

100 100 100 3 2.25

40

6.3 4-6.3 100 100 100 100

50

50 50 50 3 2.25

40

10 6-10 100 100 100 100

15

15 10 10 3 2.25

40

14 9-14 100 100 15 7.5

8

4 6 4.5 3 2.25

40

18 13-18 100 100 15 7.5

8

4 6 4.5 3 2.25

40

23 17-23 50 50 15 6

6

3 4 3 3 2.25

40

32 24-32 50 50 15 6

6

3 4 3 3 2.25

40

JGV3-80 40 25-40 - - 35 17.5 - - - - 4 2

50

63 40-63 - - 35 17.5 - - - - 4 2

50

80 56-80 - - 35 17.5 - - - - 4 2

50

 

Rated power of the three-phase motor controlled by the circuit breaker (see Table 2)

Type Rated current of trip unit In(A) Rated current adjustment range (A) Standard rated power of three-phase motor (kW)
AC-3, 50Hz/60Hz
230/240V

400V

415V

440V

500V

690V
0.06 0.1-0.16 - - - - - -
0.25 0.6-0.25 - - - - - -
JGV2-32 0.4 0.25-0.4 - - - - - -
0.63 0.4-0.63 - - - - - 0.37
1 0.63-1 - - -

0.37

0.37

0.55
1.6 1-1.6 -

0.37

-

0.55

0.75

1.1
2.5 1.6-2.5 0.37

0.75

0.75

1.1

1.1

1.5
4 2.5-4 0.75

1.5

1.5

1.5

2.2

3
6.3 4-6.3 1.1

2.2

2.2 3

3.7

4
10 6-10 2.2 4 4 4

5.5

7.5
14 9-14 3

5.5

5.5

7.5

7.5

9
18 13-18 4

7.5

9 9 9 11
23 17-23 5.5 11 11

11

11 15
32 24-32 7.5 15 15

15

18.5

26
JGV3-80 40 25-40 -

18.5

- - - 30
63 40-63 -

30

- - - 45
80 56-80 - 37 - - - 55

 

The enclosure protection level is: IP20;
The operating performance of the circuit breaker (see Table 3)

Type Frame rated current Inm(A) Operating cycles per hour Operation cycle times
Power ups No power Total
1 32 120 2000 10000 12000
2 80 120 2000 10000 12000

Outline and Mounting Dimension

product5


Product detail pictures:

PriceList for Contato - GV2-M motor protector with overcurrent protection – JUHONG detail pictures

PriceList for Contato - GV2-M motor protector with overcurrent protection – JUHONG detail pictures

PriceList for Contato - GV2-M motor protector with overcurrent protection – JUHONG detail pictures

PriceList for Contato - GV2-M motor protector with overcurrent protection – JUHONG detail pictures

PriceList for Contato - GV2-M motor protector with overcurrent protection – JUHONG detail pictures


Related Product Guide:

We rely upon strategic thinking, constant modernisation in all segments, technological advances and of course upon our employees that directly participate in our success for PriceList for Contato - GV2-M motor protector with overcurrent protection – JUHONG , The product will supply to all over the world, such as: Rio de Janeiro, Toronto, Portland, Our continual availability of high grade products in combination with our excellent pre-sale and after-sales service ensures strong competitiveness in an increasingly globalized market. welcome new and old customers from all walks of life to contact us for future business relationships and mutual success!
  • The factory workers have rich industry knowledge and operational experience, we learned a lot in working with them,we are extremely grateful that we can encount a good company has excellent wokers.
    5 Stars By Stephen from Barbados - 2018.12.10 19:03
    Managers are visionary, they have the idea of "mutual benefits, continuous improvement and innovation", we have a pleasant conversation and Cooperation.
    5 Stars By Steven from Macedonia - 2017.11.29 11:09
    Write your message here and send it to us