OEM/ODM Manufacturer Magnetic Starter - Moulded Case Circuit Breaker JM1 – JUHONG
OEM/ODM Manufacturer Magnetic Starter - Moulded Case Circuit Breaker JM1 – JUHONG Detail:
Specification
Type |
Pole |
Rated current (A) |
Rated insulation voltage (V) |
Rated operation voltage (V) |
Arcing-over Distance (mm) |
Ultimate short-circuit Breaking capacity (KA) |
Service short-circuit Breaking capacity (KA) |
Operation performance |
Utilization category |
JM1-63L |
3P/4P |
6,10,16,20,25 32,40,50,63 |
660 |
380 |
0 |
25 |
18 |
1500 |
8500 |
JM1-63M |
660 |
380 |
0 |
50 |
35 |
1500 |
8500 |
||
JM1-100L |
3P/4P |
10,16,20,25,32, |
660 |
380 |
0 |
35 |
22 |
1500 |
8500 |
JM1-100M |
660 |
380 |
≤50 |
50 |
35 |
1500 |
8500 |
||
JM1-100H |
660 |
380 |
≤50 |
85 |
50 |
1000 |
7000 |
||
JM1-225L |
3P/4P |
100, 125, 160, 180, 200, 225 |
660 |
380 |
≤50 |
35 |
22 |
1000 |
7000 |
JM1-225M |
660 |
380 |
≤50 |
50 |
35 |
1000 |
7000 |
||
JM1-225H |
660 |
380 |
≤50 |
85 |
50 |
1000 |
7000 |
||
JM1-400L |
3P/4P |
225, 250, 315, 350, 400 |
660 |
380 |
≤50 |
50 |
35 |
1000 |
4000 |
JM1-400M |
660 |
380 |
≤50 |
65 |
42 |
1000 |
4000 |
||
JM1-400H |
660 |
380 |
≤50 |
65 |
42 |
1000 |
4000 |
||
JM1-630L |
3P |
400, 500, 630 |
660 |
380 |
≤100 |
50 |
35 |
1000 |
4000 |
JM1-630M |
660 |
380 |
≤100 |
65 |
42 |
1000 |
4000 |
||
JM1-630H |
660 |
380 |
≤100 |
65 |
65 |
1000 |
4000 |
||
JM1-800M |
3P |
630, 700, 800 |
660 |
380 |
≤100 |
75 |
50 |
1000 |
4000 |
JM1-800H |
660 |
380 |
≤100 |
100 |
65 |
1000 |
4000 |
||
JM1-1250M |
3P |
1000, 1250 |
660 |
380 |
≤100 |
100 |
65 |
1000 |
4000 |
JM1-1250H |
660 |
380 |
≤100 |
125 |
75 |
1000 |
4000 |
||
JM1-1600M |
3P |
1600 |
660 |
380 |
≤100 |
150 |
80 |
1000 |
4000 |
Note
1.The MCCB has L; M; H types according to their rated limit short-circuit breaking capacity.
2.The MCCB is advantageous for its compact body, high breaking capacity(some even on flying arc), short arc-casting.
3.The MCCB has function of insulation wit its mark
4.The product complies with IEC60947-2, GB14048.2. Type code & signification
5.N-P type from 4-P has 3 types: A type: N-P without current tripper(normally open);
6.B type: N-P without current tripper working together with other 3P;
7.C type: N-P without current tripper working together with other 3P;
8.No code for distribution type breakers, 2 for motor-protection type;
9.No-code for distribution type breakers, 2 for motor-protection type;
It can be divided into L (common) type, M (standard) type and H (high) type. L type with connecting current equal to relevant frame level and M type with breaking capacity equaling to their frame level according to their rated limited short short-circuit breaking capacity (l c u).
10.Normal working situation
11.Altitude 2000m and below;
12.Ambient temperature no higher than+40ºC(45ºC for watercraft)no less than-5ºC;
13.Stand moist air;
14.Stand salty&oil mildew;
15.Most gradient 22.5°;
16.Atmosphere without corrupt&electric air and no danger of explosion;
17.Without rain effect.
Product detail pictures:
Related Product Guide:
So as to provide you with ease and enlarge our business, we even have inspectors in QC Crew and guarantee you our best company and solution for OEM/ODM Manufacturer Magnetic Starter - Moulded Case Circuit Breaker JM1 – JUHONG , The product will supply to all over the world, such as: Zurich, Brazil, Belgium, As an experienced factory we also accept customized order and make it same as your picture or sample specifying specification and customer design packing. The main goal of the company is to live a satisfactory memory to all the customers, and establish a long term win-win business relationship. For more information, please contact us. And It is our great pleasure if you like to have a personally meeting in our office.
By mary rash from Nigeria - 2018.11.11 19:52
After the signing of the contract, we received satisfactory goods in a short term, this is a commendable manufacturer.
By Natalie from Germany - 2018.07.26 16:51