OEM Factory for Contactor For Ac Unit - Magnetic Starter LE1 Series – JUHONG
OEM Factory for Contactor For Ac Unit - Magnetic Starter LE1 Series – JUHONG Detail:
Main Parameters And Technical Performance
● The main technical performance indicators and component equipment of the starter (see Table 1);
● The starter rated control circuit voltage Us is: AC 50/60Hz, 24V, 42V, 110V, 220/230V, 240V,
380/400V, 415V, 440V, 480V, 6OOV;
● Range of action:
○ Pull-in voltage: 50 or 60H 80%Us-110% Us; 50/60Hz 85%Us~110%Us;
○ Release voltage: 20%Us-75%Us
● The operating range of the starter with thermal (overload) relay has the operating characteristics
of thermal relay;
5. The operating frequency with thermal relay is 30 times/hour;
Technical Parameters
Type |
Maximum power AC3 duty(KW) |
Rated current(A) |
Type of enclosure |
Suitable Thermal Relay(A) |
|||||
220V 230V |
380V 400V |
415V |
440V |
500V |
660V 690V |
||||
JLE1-D09 |
2.2 |
4 |
4 |
4 |
5.5 |
5.5 |
9 |
IP42 IP65 |
JLR2-D1312 JLR2-D1314 |
JLE1-D12 |
3 |
5.5 |
5.5 |
5.5 |
7.5 |
7.5 |
12 |
IP42 IP55 |
JLR2-D1316 |
JLE1-D18 |
4 |
7.5 |
9 |
9 |
10 |
10 |
18 |
IP42 IP55 |
JLR2-D1321 |
JLE1-D25 |
5.5 |
11 |
11 |
11 |
15 |
15 |
25 |
IP42 IP55 |
JLR2-D1322 JLR2-D2353 |
JLE1-D32 |
7.5 |
15 |
15 |
15 |
18.5 |
18.5 |
32 |
IP55 |
JLR2-D2355 |
JLE1-D40 |
11 |
18.5 |
22 |
22 |
22 |
30 |
40 |
IP55 |
JLR2-D3353 JLR2-D3355 |
JLE1-D50 |
15 |
22 |
25 |
30 |
30 |
33 |
50 |
IP55 |
JLR2-D3357 JLR2-D3359 |
JLE1-D65 |
18.5 |
30 |
37 |
37 |
37 |
37 |
65 |
IP55 |
JLR2-D3361 |
JLE1-D80 |
22 |
37 |
45 |
45 |
55 |
45 |
80 |
IP55 |
JLR2-D3363 JLR2-D3365 |
JLE1-D95 |
25 |
45 |
45 |
45 |
55 |
45 |
95 |
IP55 |
JLR2-D3365 |
Enclosure |
LE1-D09 and D12 |
Double insulated, protexted to IP 429(3) or to IP 659(4) |
|||||||
LE1-D18 and D25 |
Double insulated, protexted to IP 427(3) or to IP 557(4) |
||||||||
LE1-D32…D95 |
Metal, IP 55 to IP 559 |
||||||||
Control(2 pushbuttons mounted on enclosure cover) |
LE1-D09…D95 |
1 green Start button “I” 1red Stop/Reset button”O” |
|||||||
Connections |
LE1-D32…D95 |
Pre-wired power and control circuit connections |
|||||||
Standard control circuit voltages |
|||||||||
Volts |
24 |
42 |
48 |
110 |
220/230 |
230 |
240 |
380/400 |
440 |
50/60HZ |
B7 |
D7 |
E7 |
F7 |
M7 |
P7 |
U7 |
Q7 |
R |
Shape And Installation Dimensions(mm)
Product detail pictures:
Related Product Guide:
Our mission should be to turn out to be an innovative supplier of high-tech digital and communication devices by furnishing benefit added design and style, world-class manufacturing, and repair capabilities for OEM Factory for Contactor For Ac Unit - Magnetic Starter LE1 Series – JUHONG , The product will supply to all over the world, such as: Boston, Malaysia, Greece, We have sufficient experience in producing products according to samples or drawings. We warmly welcome customers from home and abroad to visit our company, and to cooperate with us for a splendid future together.
By Arabela from Finland - 2018.11.11 19:52
We have been engaged in this industry for many years, we appreciate the work attitude and production capacity of the company, this is a reputable and professional manufacturer.
By Naomi from Seattle - 2017.09.09 10:18