Main Parameters And Technical Performance
● The main technical performance indicators and component equipment of the starter (see Table 1);
● The starter rated control circuit voltage Us is: AC 50/60Hz, 24V, 42V, 110V, 220/230V, 240V,
380/400V, 415V, 440V, 480V, 6OOV;
● Range of action:
○ Pull-in voltage: 50 or 60H 80%Us-110% Us; 50/60Hz 85%Us~110%Us;
○ Release voltage: 20%Us-75%Us
● The operating range of the starter with thermal (overload) relay has the operating characteristics
of thermal relay;
5. The operating frequency with thermal relay is 30 times/hour;
Technical Parameters
Type |
Maximum power AC3 duty(KW) |
Rated current(A) |
Type of enclosure |
Suitable Thermal Relay(A) |
|||||
220V 230V |
380V 400V |
415V |
440V |
500V |
660V 690V |
||||
JLE1-D09 |
2.2 |
4 |
4 |
4 |
5.5 |
5.5 |
9 |
IP42 IP65 |
JLR2-D1312 JLR2-D1314 |
JLE1-D12 |
3 |
5.5 |
5.5 |
5.5 |
7.5 |
7.5 |
12 |
IP42 IP55 |
JLR2-D1316 |
JLE1-D18 |
4 |
7.5 |
9 |
9 |
10 |
10 |
18 |
IP42 IP55 |
JLR2-D1321 |
JLE1-D25 |
5.5 |
11 |
11 |
11 |
15 |
15 |
25 |
IP42 IP55 |
JLR2-D1322 JLR2-D2353 |
JLE1-D32 |
7.5 |
15 |
15 |
15 |
18.5 |
18.5 |
32 |
IP55 |
JLR2-D2355 |
JLE1-D40 |
11 |
18.5 |
22 |
22 |
22 |
30 |
40 |
IP55 |
JLR2-D3353 JLR2-D3355 |
JLE1-D50 |
15 |
22 |
25 |
30 |
30 |
33 |
50 |
IP55 |
JLR2-D3357 JLR2-D3359 |
JLE1-D65 |
18.5 |
30 |
37 |
37 |
37 |
37 |
65 |
IP55 |
JLR2-D3361 |
JLE1-D80 |
22 |
37 |
45 |
45 |
55 |
45 |
80 |
IP55 |
JLR2-D3363 JLR2-D3365 |
JLE1-D95 |
25 |
45 |
45 |
45 |
55 |
45 |
95 |
IP55 |
JLR2-D3365 |
Enclosure |
LE1-D09 and D12 |
Double insulated, protexted to IP 429(3) or to IP 659(4) |
|||||||
LE1-D18 and D25 |
Double insulated, protexted to IP 427(3) or to IP 557(4) |
||||||||
LE1-D32…D95 |
Metal, IP 55 to IP 559 |
||||||||
Control(2 pushbuttons mounted on enclosure cover) |
LE1-D09…D95 |
1 green Start button “I” 1red Stop/Reset button”O” |
|||||||
Connections |
LE1-D32…D95 |
Pre-wired power and control circuit connections |
|||||||
Standard control circuit voltages |
|||||||||
Volts |
24 |
42 |
48 |
110 |
220/230 |
230 |
240 |
380/400 |
440 |
50/60HZ |
B7 |
D7 |
E7 |
F7 |
M7 |
P7 |
U7 |
Q7 |
R |
Shape And Installation Dimensions(mm)
Product detail pictures:
Related Product Guide:
Often customer-oriented, and it's our ultimate target to become not only probably the most reputable, trustable and honest provider, but also the partner for our customers for OEM Customized Air Break Contactor - Magnetic Starter LE1 Series – JUHONG , The product will supply to all over the world, such as: Seattle, Kuala Lumpur, Qatar, In order to make more people know our products and to enlarge our market, we have devoted a lot of attention to technical innovations and improvement, as well as replacement of equipment. Last but not the least, we also pay more attention to training our managerial personnel, technicians and workers in planned way.
By Debby from Manila - 2018.11.28 16:25
The customer service reprersentative explained very detailed, service attitude is very good, reply is very timely and comprehensive, a happy communication! We hope to have a opportunity to cooperate.
By Arthur from Mexico - 2017.06.25 12:48