Mechanical Interlocked AC Contactor
Feature
Ambient air temperature of -5°C ~ 40°C, and the 24h average does not exceed 35°C.
Altitude: Altitude less than 2000m.
Atmospheric conditions: 40°C, relative humidity of the atmosphere does not exceed 50%; At a lower temperature allows a higher relative humidity, the wettest month of the monthly minimum temperature level does not exceed 25°C, the monthly mean maximum relative humidity of not more than 90%, due to temperature changes in the product of condensation occurring on the measures must be taken.
Pollution degree: 3;
Installation Category: III class;
Installation conditions: The mounting surface and the vertical gradient is not greater than ± 5°.
Impulsive vibration: Product should be installed and used in the absence of a significant shake and shock, vibrations JLC2-D AC Contactor.
Type | Rated current
AC-3(A) |
Controlled power (KW) | ||||
220V |
380V | 415V | 440V |
660V |
||
JLC2-09N | 9 |
2.2 |
4 |
4 |
4 | 5.5 |
JLC2-12N | 12 |
5.5 |
5.5 |
5.5 |
5.5 |
7.5 |
JLC2-18N | 18 |
7.5 |
7.5 |
9 |
9 | 10 |
JLC2-25N | 25 |
5.5 |
11 |
11 |
11 | 15 |
JLC2-32N | 32 |
7.5 |
15 |
15 |
15 |
18.5 |
JLC2-40N | 40 |
18.5 |
18.5 |
22 |
22 |
30 |
JLC2-50N | 50 |
15 |
22 |
25 |
30 |
33 |
JLC2-65N | 63 |
18.5 |
30 |
37 |
37 |
37 |
JLC2-80N | 80 |
22 |
37 |
45 |
45 |
45 |
JLC2-95N | 95 |
22 |
45 |
45 |
45 |
41 |
JLC2-115N | 115 |
30 |
55 |
59 |
59 |
80 |
JLC2-150N | 150 |
40 |
75 |
80 |
80 |
100 |
JLC2-170N | 170 |
55 |
90 |
100 |
100 |
110 |
JLC2-205N | 205 |
63 |
110 |
110 |
110 |
129 |
JLC2-245N | 145 |
75 |
132 |
132 |
132 |
160 |
JLC2-300N | 300 |
100 |
160 |
200 |
200 |
220 |
JLC2-410N | 410 |
110 |
220 |
250 |
250 |
280 |
JLC2-475N | 475 |
147 |
265 |
280 |
280 |
355 |
JLC2-620N | 620 |
200 |
335 |
400 |
400 |
450 |
Outline And Mounting Dimension
FIGURE 1 JLC2-09N~32N(Horizontal installation)
FIGURE 2 JLC2-40N~95N(Horizontal installation)
JLC2-09N~170N(Horizontal installation)
Type | Amax | Bmax | Cmax | g | h | ø |
JLC2-09N~12N | 81 | 106 | 85 | 95 | - | 4.5 |
JLC2-18N | 81 | 106 | 87 | 95 | - | 4.5 |
JLC2-25N | 94 | 129 | 100 | 112 | - | 4.5 |
JLC2-32N | 96 | 129 | 103 | 112 | - | 4.5 |
JLC2-40N~65N | 129 | 165 | 116 | 50 | 90 | 6.5 |
JLC2-80N~95N | 129 | 185 | 127 | 57 | 96 | 6.5 |
JLC2-115N~170N | 162 | 268 | 133 | 242/256 | - | 6.5 |
JLC2-F115N~F330N,JLC2-205N~300N(Horizontal installation)
Type | a | P | P1 | Q1 | S | ø | f | b | b1 | M | c | L | G | J | H | ø1 | Y | X1 | |
≤500V | >500V | ||||||||||||||||||
JLC2-F115 | 346 |
37 |
78 | 60 | 15 |
M6 |
109 | 162 |
137 |
147 | 171 | 107 | 80 | 72 | 120/106 | 6.5 | 57 | 10 | 15 |
JLC2-F1154 | 420 |
37 |
78 | 60 | 15 |
M6 |
109 | 162 |
137 |
147 | 171 | 107 | 80 | 109 | 120/106 | 6.5 | 75.5 | 10 | 15 |
JLC2-F150 | 346 |
40 |
72 | 57.5 | 20 |
M8 |
109 | 170 |
137 |
150 | 171 | 107 | 80 | 72 | 120/106 | 6.5 | 57 | 10 | 15 |
JLC2-F1504 | 420 |
40 |
72 | 55.5 | 20 |
M8 |
109 | 170 |
137 |
150 | 171 | 107 | 80 | 109 | 120/106 | 6.5 | 75.5 | 10 | 15 |
JLC2-F185, 205 | 357 |
40 |
78 | 59.5 | 20 |
M8 |
117 | 174 |
137 |
154 | 181 | 113.5 | 80 | 78 | 120/106 | 6.5 | 59.5 | 10 | 15 |
JLC2-F1854 | 437 |
40 |
78 | 59.5 | 20 |
M8 |
117 | 174 |
137 |
154 | 181 | 113.5 | 80 | 118 | 120/106 | 6.5 | 79.5 | 10 | 15 |
JLC2-F225,245 | 357 |
48 |
62 | 51.5 | 25 |
M10 |
117 | 197 |
137 |
175 | 181 | 113.5 | 80 | 78 | 120/106 | 6.5 | 59.5 | 10 | 15 |
JLC2-F2254 | 437 |
48 |
54 | 47.5 | 25 |
M10 |
117 | 197 |
137 |
175 | 181 | 113.5 | 80 | 118 | 120/106 | 6.5 | 79.5 | 10 | 15 |
JLC2-F265 | 424 |
48 |
99 | 66.5 | 25 |
M10 |
143 | 203 |
145 |
178 | 213 | 141 | 96 | 109 | 120/106 | 6.5 | 61.5 | 10 | 15 |
JLC2-F2654 | 520 |
48 |
99 | 66.5 | 25 |
M10 |
143 | 203 |
145 |
178 | 213 | 141 | 96 | 157 | 120/106 | 6.5 | 85.5 | 10 | 15 |
JLC2-F330,400 | 445 |
48 |
105 | 74 | 25 |
M10 |
143 | 206 |
145 |
181 | 219 | 145 | 96 | 122 | 120/106 | 6.5 | 65.5 | 10 | 15 |
JLC2-F3304 | 541 |
48 |
105 | 74 | 25 |
M10 |
143 | 206 |
145 |
181 | 219 | 145 | 96 | 170 | 120/106 | 6.5 | 89.5 | 10 | 15 |
Ordering Instructions
When placing an order,you should point out the below:
1. Product name and model, rated operational voltage and frequency of coil, order quantity.
Ordering example: Reversing Contactor JLC2-40N AC 220V 50Hz 60PCS.
FAQ
Q: Can i get sample for reference?
A: Yes
Q: Can I get catalog from your company?
A: Sure, please kindly tell us what kind of product you are looking for and provide more information. We will send catalog to you according to your requirement, includes MOQ and price range.
Q: How soon can you deliver?
A: It really depends when you send the order. Normally for 3000pcs order, less than 30 days.
Q: What’s your email address?
A: Please send us inquiry in ‘contact us’ area. We can receive then.
Q: How much is the shipping cost ?
A: It really depends your order volume. Please confirm your order quantity so we can work out shipping cost.
Six advantages:
1.Beautiful atmosphere
2.Small size and high segment
3.Double wire disconnect
4.Excellent cooper wire
5.Overload protection
Green product and environment protection
Shipping way
By sea, by air, by express carrier
Certificate