Manufacturer of Electric Circuit Breaker - GV2-M motor protector with overcurrent protection – JUHONG
Manufacturer of Electric Circuit Breaker - GV2-M motor protector with overcurrent protection – JUHONG Detail:
Technical Characteristic
Type | Rated current of trip unit In(A) | Setting current adjustment range (A) | Rated ultimate short-circuit breaking capacity lcu (kA), rated operating short-circuit breaking capacity lcs (kA) | Arcing distance (mm) | |||||||||
230/240V | 400/415V | 440V | 500V | 690V | |||||||||
Icu | Ics | Icu | Ics |
Icu |
Ics | Icu | Ics | Icu | Ics | ||||
0.16 |
0.1-0.16 |
100 | 100 | 100 | 100 |
100 |
100 | 100 | 100 | 100 | 100 |
40 |
|
0.25 |
0.16-0.25 |
100 | 100 | 100 | 100 |
100 |
100 | 100 | 100 | 100 | 100 |
40 |
|
JGV2-32 | 0.4 |
0.25-0.4 |
100 | 100 | 100 | 100 |
100 |
100 | 100 | 100 | 100 | 100 |
40 |
0.63 |
0.4-0.63 |
100 | 100 | 100 | 100 |
100 |
100 | 100 | 100 | 100 | 100 |
40 |
|
1 | 0.63-1 | 100 | 100 | 100 | 100 |
100 |
100 | 100 | 100 | 100 | 100 |
40 |
|
1.6 | 1-1.6 | 100 | 100 | 100 | 100 |
100 |
100 | 100 | 100 | 100 | 100 |
40 |
|
2.5 | 1.6-2.5 | 100 | 100 | 100 | 100 |
100 |
100 | 100 | 100 | 3 | 2.25 |
40 |
|
4 | 2.5-4 | 100 | 100 | 100 | 100 |
100 |
100 | 100 | 100 | 3 | 2.25 |
40 |
|
6.3 | 4-6.3 | 100 | 100 | 100 | 100 |
50 |
50 | 50 | 50 | 3 | 2.25 |
40 |
|
10 | 6-10 | 100 | 100 | 100 | 100 |
15 |
15 | 10 | 10 | 3 | 2.25 |
40 |
|
14 | 9-14 | 100 | 100 | 15 | 7.5 |
8 |
4 | 6 | 4.5 | 3 | 2.25 |
40 |
|
18 | 13-18 | 100 | 100 | 15 | 7.5 |
8 |
4 | 6 | 4.5 | 3 | 2.25 |
40 |
|
23 | 17-23 | 50 | 50 | 15 | 6 |
6 |
3 | 4 | 3 | 3 | 2.25 |
40 |
|
32 | 24-32 | 50 | 50 | 15 | 6 |
6 |
3 | 4 | 3 | 3 | 2.25 |
40 |
|
JGV3-80 | 40 | 25-40 | - | - | 35 | 17.5 | - | - | - | - | 4 | 2 |
50 |
63 | 40-63 | - | - | 35 | 17.5 | - | - | - | - | 4 | 2 |
50 |
|
80 | 56-80 | - | - | 35 | 17.5 | - | - | - | - | 4 | 2 |
50 |
Rated power of the three-phase motor controlled by the circuit breaker (see Table 2)
Type | Rated current of trip unit In(A) | Rated current adjustment range (A) | Standard rated power of three-phase motor (kW) | |||||
AC-3, 50Hz/60Hz | ||||||||
230/240V |
400V |
415V |
440V |
500V |
690V | |||
0.06 | 0.1-0.16 | - | - | - | - | - | - | |
0.25 | 0.6-0.25 | - | - | - | - | - | - | |
JGV2-32 | 0.4 | 0.25-0.4 | - | - | - | - | - | - |
0.63 | 0.4-0.63 | - | - | - | - | - | 0.37 | |
1 | 0.63-1 | - | - | - |
0.37 |
0.37 |
0.55 | |
1.6 | 1-1.6 | - |
0.37 |
- |
0.55 |
0.75 |
1.1 | |
2.5 | 1.6-2.5 | 0.37 |
0.75 |
0.75 |
1.1 |
1.1 |
1.5 | |
4 | 2.5-4 | 0.75 |
1.5 |
1.5 |
1.5 |
2.2 |
3 | |
6.3 | 4-6.3 | 1.1 |
2.2 |
2.2 | 3 |
3.7 |
4 | |
10 | 6-10 | 2.2 | 4 | 4 | 4 |
5.5 |
7.5 | |
14 | 9-14 | 3 |
5.5 |
5.5 |
7.5 |
7.5 |
9 | |
18 | 13-18 | 4 |
7.5 |
9 | 9 | 9 | 11 | |
23 | 17-23 | 5.5 | 11 | 11 |
11 |
11 | 15 | |
32 | 24-32 | 7.5 | 15 | 15 |
15 |
18.5 |
26 | |
JGV3-80 | 40 | 25-40 | - |
18.5 |
- | - | - | 30 |
63 | 40-63 | - |
30 |
- | - | - | 45 | |
80 | 56-80 | - | 37 | - | - | - | 55 |
The enclosure protection level is: IP20;
The operating performance of the circuit breaker (see Table 3)
Type | Frame rated current Inm(A) | Operating cycles per hour | Operation cycle times | ||
Power ups | No power | Total | |||
1 | 32 | 120 | 2000 | 10000 | 12000 |
2 | 80 | 120 | 2000 | 10000 | 12000 |
Outline and Mounting Dimension
Product detail pictures:
Related Product Guide:
We have quite a few great team customers very good at internet marketing, QC, and dealing with kinds of troublesome trouble while in the output approach for Manufacturer of Electric Circuit Breaker - GV2-M motor protector with overcurrent protection – JUHONG , The product will supply to all over the world, such as: Cannes, Yemen, Egypt, With strong technical strength and advanced production equipment, and SMS people purposefully , professional, dedicated spirit of enterprise. Enterprises took the lead through the ISO 9001:2008 international quality management system certification, CE certification EU ; CCC.SGS.CQC other related product certification. We look forward to reactivating our company connection.
By Kama from Cyprus - 2018.05.22 12:13
This supplier stick to the principle of "Quality first, Honesty as base", it is absolutely to be trust.
By Bess from Poland - 2017.09.09 10:18
Write your message here and send it to us