High reputation Residual Current Circuit Breaker - Moulded Case Circuit Breaker JM1 – JUHONG
High reputation Residual Current Circuit Breaker - Moulded Case Circuit Breaker JM1 – JUHONG Detail:
Specification
Type |
Pole |
Rated current (A) |
Rated insulation voltage (V) |
Rated operation voltage (V) |
Arcing-over Distance (mm) |
Ultimate short-circuit Breaking capacity (KA) |
Service short-circuit Breaking capacity (KA) |
Operation performance |
Utilization category |
JM1-63L |
3P/4P |
6,10,16,20,25 32,40,50,63 |
660 |
380 |
0 |
25 |
18 |
1500 |
8500 |
JM1-63M |
660 |
380 |
0 |
50 |
35 |
1500 |
8500 |
||
JM1-100L |
3P/4P |
10,16,20,25,32, |
660 |
380 |
0 |
35 |
22 |
1500 |
8500 |
JM1-100M |
660 |
380 |
≤50 |
50 |
35 |
1500 |
8500 |
||
JM1-100H |
660 |
380 |
≤50 |
85 |
50 |
1000 |
7000 |
||
JM1-225L |
3P/4P |
100, 125, 160, 180, 200, 225 |
660 |
380 |
≤50 |
35 |
22 |
1000 |
7000 |
JM1-225M |
660 |
380 |
≤50 |
50 |
35 |
1000 |
7000 |
||
JM1-225H |
660 |
380 |
≤50 |
85 |
50 |
1000 |
7000 |
||
JM1-400L |
3P/4P |
225, 250, 315, 350, 400 |
660 |
380 |
≤50 |
50 |
35 |
1000 |
4000 |
JM1-400M |
660 |
380 |
≤50 |
65 |
42 |
1000 |
4000 |
||
JM1-400H |
660 |
380 |
≤50 |
65 |
42 |
1000 |
4000 |
||
JM1-630L |
3P |
400, 500, 630 |
660 |
380 |
≤100 |
50 |
35 |
1000 |
4000 |
JM1-630M |
660 |
380 |
≤100 |
65 |
42 |
1000 |
4000 |
||
JM1-630H |
660 |
380 |
≤100 |
65 |
65 |
1000 |
4000 |
||
JM1-800M |
3P |
630, 700, 800 |
660 |
380 |
≤100 |
75 |
50 |
1000 |
4000 |
JM1-800H |
660 |
380 |
≤100 |
100 |
65 |
1000 |
4000 |
||
JM1-1250M |
3P |
1000, 1250 |
660 |
380 |
≤100 |
100 |
65 |
1000 |
4000 |
JM1-1250H |
660 |
380 |
≤100 |
125 |
75 |
1000 |
4000 |
||
JM1-1600M |
3P |
1600 |
660 |
380 |
≤100 |
150 |
80 |
1000 |
4000 |
Note
1.The MCCB has L; M; H types according to their rated limit short-circuit breaking capacity.
2.The MCCB is advantageous for its compact body, high breaking capacity(some even on flying arc), short arc-casting.
3.The MCCB has function of insulation wit its mark
4.The product complies with IEC60947-2, GB14048.2. Type code & signification
5.N-P type from 4-P has 3 types: A type: N-P without current tripper(normally open);
6.B type: N-P without current tripper working together with other 3P;
7.C type: N-P without current tripper working together with other 3P;
8.No code for distribution type breakers, 2 for motor-protection type;
9.No-code for distribution type breakers, 2 for motor-protection type;
It can be divided into L (common) type, M (standard) type and H (high) type. L type with connecting current equal to relevant frame level and M type with breaking capacity equaling to their frame level according to their rated limited short short-circuit breaking capacity (l c u).
10.Normal working situation
11.Altitude 2000m and below;
12.Ambient temperature no higher than+40ºC(45ºC for watercraft)no less than-5ºC;
13.Stand moist air;
14.Stand salty&oil mildew;
15.Most gradient 22.5°;
16.Atmosphere without corrupt&electric air and no danger of explosion;
17.Without rain effect.
Product detail pictures:
Related Product Guide:
We not only will try our best to offer excellent services to every customer, but also are ready to receive any suggestion offered by our customers for High reputation Residual Current Circuit Breaker - Moulded Case Circuit Breaker JM1 – JUHONG , The product will supply to all over the world, such as: Romania, Madrid, Saudi Arabia, In order to meet our market demands, we have paied more attention to the quality of our products and services. Now we can meet customers' special requirements for special designs. We persistently develop our enterprise spirit "quality lives the enterprise, credit assures cooperation and keep the motto in our minds: customers first.
By Esther from Spain - 2018.02.12 14:52
We feel easy to cooperate with this company, the supplier is very responsible, thanks.There will be more in-depth cooperation.
By Doris from Colombia - 2017.06.16 18:23