We stick to the principle of "quality first, service first, continuous improvement and innovation to meet the customers" for the management and "zero defect, zero complaints" as the quality objective. To perfect our service, we provide the products with the good quality at the reasonable price for Relay My4, Mini Contactor, Definite Time Relay, Our company has already set up a professional, creative and responsible team to develop clients with the multi-win principle.
High Quality for Mccb Merlin Gerin - Motor Protector With Overload Protection JGV2 – JUHONG Detail:

Technical Characteristic

Type Rated current of trip unit In(A) Setting current adjustment range (A) Rated ultimate short-circuit breaking capacity lcu (kA), rated operating short-circuit breaking capacity lcs (kA) Arcing distance (mm)
230/240V 400/415V 440V 500V 690V
Icu Ics Icu Ics

Icu

Ics Icu Ics Icu Ics
0.16

0.1-0.16

100 100 100 100

100

100 100 100 100 100

40

0.25

0.16-0.25

100 100 100 100

100

100 100 100 100 100

40

JGV2-32 0.4

0.25-0.4

100 100 100 100

100

100 100 100 100 100

40

0.63

0.4-0.63

100 100 100 100

100

100 100 100 100 100

40

1 0.63-1 100 100 100 100

100

100 100 100 100 100

40

1.6 1-1.6 100 100 100 100

100

100 100 100 100 100

40

2.5 1.6-2.5 100 100 100 100

100

100 100 100 3 2.25

40

4 2.5-4 100 100 100 100

100

100 100 100 3 2.25

40

6.3 4-6.3 100 100 100 100

50

50 50 50 3 2.25

40

10 6-10 100 100 100 100

15

15 10 10 3 2.25

40

14 9-14 100 100 15 7.5

8

4 6 4.5 3 2.25

40

18 13-18 100 100 15 7.5

8

4 6 4.5 3 2.25

40

23 17-23 50 50 15 6

6

3 4 3 3 2.25

40

32 24-32 50 50 15 6

6

3 4 3 3 2.25

40

JGV3-80 40 25-40 - - 35 17.5 - - - - 4 2

50

63 40-63 - - 35 17.5 - - - - 4 2

50

80 56-80 - - 35 17.5 - - - - 4 2

50

 

Rated power of the three-phase motor controlled by the circuit breaker (see Table 2)

The enclosure protection level is: IP20;
The operating performance of the circuit breaker (see Table 3)

Type Frame rated current Inm(A) Operating cycles per hour Operation cycle times
Power ups No power Total
1 32 120 2000 10000 12000
2 80 120 2000 10000 12000

Outline and Mounting Dimension

product5


Product detail pictures:


Related Product Guide:

We not only will try our greatest to offer superb companies to just about every buyer, but also are ready to receive any suggestion offered by our shoppers for High Quality for Mccb Merlin Gerin - Motor Protector With Overload Protection JGV2 – JUHONG , The product will supply to all over the world, such as: Tanzania, moldova, Jamaica, Welcome to visit our company and factory, there are various products displayed in our showroom that will meet your expectation, meanwhile, if you are convenient to visit our website, our sales staff will try their efforts to provide you the best service
Hope that the company could stick to the enterprise spirit of "Quality, Efficiency, Innovation and Integrity", it will be better and better in the future.
5 Stars By Renata from Luxemburg - 2017.08.21 14:13
Good quality and fast delivery, it's very nice. Some products have a little bit problem, but the supplier replaced timely, overall, we are satisfied.
5 Stars By Joanna from Qatar - 2018.07.12 12:19
Write your message here and send it to us