High definition Schneider Mpcb - GV2-M motor protector with overcurrent protection – JUHONG

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

We love an incredibly fantastic standing amid our consumers for our superb item high quality, aggressive rate and also the finest assistance for Mechanical Interlock Ac Contactor, Definite Time Relay, Motor Circuit Protector, We welcome new and old customers from all walks of life to contact us for future business relationships and achieving mutual success!
High definition Schneider Mpcb - GV2-M motor protector with overcurrent protection – JUHONG Detail:

Technical Characteristic

Type Rated current of trip unit In(A) Setting current adjustment range (A) Rated ultimate short-circuit breaking capacity lcu (kA), rated operating short-circuit breaking capacity lcs (kA) Arcing distance (mm)
230/240V 400/415V 440V 500V 690V
Icu Ics Icu Ics

Icu

Ics Icu Ics Icu Ics
0.16

0.1-0.16

100 100 100 100

100

100 100 100 100 100

40

0.25

0.16-0.25

100 100 100 100

100

100 100 100 100 100

40

JGV2-32 0.4

0.25-0.4

100 100 100 100

100

100 100 100 100 100

40

0.63

0.4-0.63

100 100 100 100

100

100 100 100 100 100

40

1 0.63-1 100 100 100 100

100

100 100 100 100 100

40

1.6 1-1.6 100 100 100 100

100

100 100 100 100 100

40

2.5 1.6-2.5 100 100 100 100

100

100 100 100 3 2.25

40

4 2.5-4 100 100 100 100

100

100 100 100 3 2.25

40

6.3 4-6.3 100 100 100 100

50

50 50 50 3 2.25

40

10 6-10 100 100 100 100

15

15 10 10 3 2.25

40

14 9-14 100 100 15 7.5

8

4 6 4.5 3 2.25

40

18 13-18 100 100 15 7.5

8

4 6 4.5 3 2.25

40

23 17-23 50 50 15 6

6

3 4 3 3 2.25

40

32 24-32 50 50 15 6

6

3 4 3 3 2.25

40

JGV3-80 40 25-40 - - 35 17.5 - - - - 4 2

50

63 40-63 - - 35 17.5 - - - - 4 2

50

80 56-80 - - 35 17.5 - - - - 4 2

50

 

Rated power of the three-phase motor controlled by the circuit breaker (see Table 2)

Type Rated current of trip unit In(A) Rated current adjustment range (A) Standard rated power of three-phase motor (kW)
AC-3, 50Hz/60Hz
230/240V

400V

415V

440V

500V

690V
0.06 0.1-0.16 - - - - - -
0.25 0.6-0.25 - - - - - -
JGV2-32 0.4 0.25-0.4 - - - - - -
0.63 0.4-0.63 - - - - - 0.37
1 0.63-1 - - -

0.37

0.37

0.55
1.6 1-1.6 -

0.37

-

0.55

0.75

1.1
2.5 1.6-2.5 0.37

0.75

0.75

1.1

1.1

1.5
4 2.5-4 0.75

1.5

1.5

1.5

2.2

3
6.3 4-6.3 1.1

2.2

2.2 3

3.7

4
10 6-10 2.2 4 4 4

5.5

7.5
14 9-14 3

5.5

5.5

7.5

7.5

9
18 13-18 4

7.5

9 9 9 11
23 17-23 5.5 11 11

11

11 15
32 24-32 7.5 15 15

15

18.5

26
JGV3-80 40 25-40 -

18.5

- - - 30
63 40-63 -

30

- - - 45
80 56-80 - 37 - - - 55

 

The enclosure protection level is: IP20;
The operating performance of the circuit breaker (see Table 3)

Type Frame rated current Inm(A) Operating cycles per hour Operation cycle times
Power ups No power Total
1 32 120 2000 10000 12000
2 80 120 2000 10000 12000

Outline and Mounting Dimension

product5


Product detail pictures:


Related Product Guide:

With this motto in mind, we have become one of the most technologically innovative, cost-efficient, and price-competitive manufacturers for High definition Schneider Mpcb - GV2-M motor protector with overcurrent protection – JUHONG , The product will supply to all over the world, such as: Romania, Paraguay, Botswana, We have customers from more than 20 countries and our reputation has been recognized by our esteemed customers. Never-ending improvement and striving for 0% deficiency are our two main quality policies. Should you need anything, don't hesitate to contact us.
We are a small company that has just started, but we get the company leader's attention and gave us a lot of help. Hope we can make progress together!
5 Stars By Nick from Tunisia - 2018.07.26 16:51
With a positive attitude of "regard the market, regard the custom, regard the science", the company works actively to do research and development. Hope we have a future business relationships and achieving mutual success.
5 Stars By Rose from Sevilla - 2018.06.19 10:42
Write your message here and send it to us