Good User Reputation for Ac Unit Contactor Replacement - Siemens Type AC Contactor J3TF – JUHONG
Good User Reputation for Ac Unit Contactor Replacement - Siemens Type AC Contactor J3TF – JUHONG Detail:
Type | J3TF-9/12 | J3TF-16/22 | J3TF-32 | J3TF-45/63 | J3TF-75/85 | J3TF-110/140 | J3TF-170/205 | J3TF-250/300 | J3TF-400/475 | |
Mechanical Endurance(X106) |
10 | 10 | 10 | 8 | 8 | 8 | 8 | 8 | 8 | |
Conventional thermal current(A) |
20 | 30 | 45 | 80 | 100 | 160 | 210 | 300 | 400/550 | |
Rated insulation voltage(V) |
660 | 660 | 660 | 1000 | 1000 | 1000 | 1000 | 1000 | 1000 | |
Rated operating current(A) |
AC-3 | 9/12 | 16/22 | 32 | 45/63 | 75/85 | 110/140 | 170/205 | 250/300 | 400/475 |
AC-4 | 3.3/4.3 | 7.7/8.5 | 15.6 | 24/28 | 34/42 | 54/68 | 75/96 | 110/125 | 150 | |
Power of controllablemotor(KW) AC-3 | 380V | 4/5.5 | 7.5/11 | 15 | 22/30 | 37/45 | 55/75 | 90/110 | 132/160 | 200/250 |
660V | 5.5/7.5 | 11 | 23 | 39/55 | 67 | 100 | 156 | 235 | 375 | |
Power of controllablemotor(KW) AC-4 | 380V | 1.4/1.9 | 3.5/4 | 7.5 | 12/14 | 17/21 | 27/35 | 38/50 | 58/66 | 81 |
660V | 2.4/3.3 | 6/6.6 | 13 | 20.8/24 | 29.5/36 | 46.9/60 | 66/86 | 100/114 | 140 | |
Frequency of operation (I/h) |
AC-3 | 1000 | 750 | 750 | 1200/1000 | 1000/850 | 1000/750 | 700/500 | 700/500 | 500/420 |
AC-4 | 250 | 250 | 250 | 400/300 | 300/250 | 300/200 | 200/130 | 200/130 | 150 | |
Electrical endurance (X106) |
AC-3 | 1.2 | 1.2 | 1.2 | 1.2 | 1.2 | 1.2 | 1.2 | 1.2 | 1.2 |
AC-4 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | |
Operating voltage range of coil |
(0.8-1.1)Ue | |||||||||
Power consumption of coil |
Atracting (VA) |
10 | 10 | 12.1 | 17 | 32 | 39 | 58 | 84 | 115 |
Starting (VA) |
68 | 69 | 101 | 183 | 330 | 550 | 910 | 1430 | 2450 | |
Rated insulation voltageof auxiliary contacts(V) | 690 | 690 | 690 | 690 | 690 | 690 | 690 | 690 | 690 | 690 |
Conventional thermal currentof auxiliary contacts(A) | 10 | 10 | 10 | 10 | 10 | 10 | 10 | 10 | 10 | 10 |
Rated operating currentof auxiliary contacts(A) | AC15 380/220 |
6/10 | 6/10 | 4/6 | 4/6 | 4/6 | 4/6 | 4/6 | 4/6 | 4/6 |
DC13 220v |
0.45 | 0.45 | 0.45 | 0.45 | 0.45 | 0.45 | 0.45 | 0.45 | 0.45 | |
Rated voltage of the control coil(V) |
50HZ | 24 36 48 110 127 220 380,etc | ||||||||
60HZ | 24 110 220 440 etc |
Product detail pictures:
Related Product Guide:
As for aggressive rates, we believe that you will be searching far and wide for anything that can beat us. We can easily state with absolute certainty that for such good quality at such charges we are the lowest around for Good User Reputation for Ac Unit Contactor Replacement - Siemens Type AC Contactor J3TF – JUHONG , The product will supply to all over the world, such as: Luxemburg, Amman, South Africa, Should any of these items be of interest to you, please let us know. We'll be satisfied to give you a quotation upon receipt of one's detailed specifications. We have our personal experienced R&D enginners to meet any of one's requriements, We appear forward to receiving your enquires soon'and hope to have the opportunity to work together with you in the future. Welcome to check out our company.
By Roxanne from Malta - 2018.12.05 13:53
Speaking of this cooperation with the Chinese manufacturer, I just want to say"well dodne", we are very satisfied.
By King from Durban - 2018.06.19 10:42
Write your message here and send it to us