Our commission would be to serve our customers and clientele with very best excellent and aggressive portable digital products for Air Conditioner Contactor, Ls Mccb, Manual Motor Protector, To acquire a consistent, profitable, and constant growth by getting a competitive advantage, and by continuously increasing the value added to our shareholders and our employee.
Factory Supply Circuit Breaker - GV2-M motor protector with overcurrent protection – JUHONG Detail:

Technical Characteristic

Type Rated current of trip unit In(A) Setting current adjustment range (A) Rated ultimate short-circuit breaking capacity lcu (kA), rated operating short-circuit breaking capacity lcs (kA) Arcing distance (mm)
230/240V 400/415V 440V 500V 690V
Icu Ics Icu Ics

Icu

Ics Icu Ics Icu Ics
0.16

0.1-0.16

100 100 100 100

100

100 100 100 100 100

40

0.25

0.16-0.25

100 100 100 100

100

100 100 100 100 100

40

JGV2-32 0.4

0.25-0.4

100 100 100 100

100

100 100 100 100 100

40

0.63

0.4-0.63

100 100 100 100

100

100 100 100 100 100

40

1 0.63-1 100 100 100 100

100

100 100 100 100 100

40

1.6 1-1.6 100 100 100 100

100

100 100 100 100 100

40

2.5 1.6-2.5 100 100 100 100

100

100 100 100 3 2.25

40

4 2.5-4 100 100 100 100

100

100 100 100 3 2.25

40

6.3 4-6.3 100 100 100 100

50

50 50 50 3 2.25

40

10 6-10 100 100 100 100

15

15 10 10 3 2.25

40

14 9-14 100 100 15 7.5

8

4 6 4.5 3 2.25

40

18 13-18 100 100 15 7.5

8

4 6 4.5 3 2.25

40

23 17-23 50 50 15 6

6

3 4 3 3 2.25

40

32 24-32 50 50 15 6

6

3 4 3 3 2.25

40

JGV3-80 40 25-40 - - 35 17.5 - - - - 4 2

50

63 40-63 - - 35 17.5 - - - - 4 2

50

80 56-80 - - 35 17.5 - - - - 4 2

50

 

Rated power of the three-phase motor controlled by the circuit breaker (see Table 2)

Type Rated current of trip unit In(A) Rated current adjustment range (A) Standard rated power of three-phase motor (kW)
AC-3, 50Hz/60Hz
230/240V

400V

415V

440V

500V

690V
0.06 0.1-0.16 - - - - - -
0.25 0.6-0.25 - - - - - -
JGV2-32 0.4 0.25-0.4 - - - - - -
0.63 0.4-0.63 - - - - - 0.37
1 0.63-1 - - -

0.37

0.37

0.55
1.6 1-1.6 -

0.37

-

0.55

0.75

1.1
2.5 1.6-2.5 0.37

0.75

0.75

1.1

1.1

1.5
4 2.5-4 0.75

1.5

1.5

1.5

2.2

3
6.3 4-6.3 1.1

2.2

2.2 3

3.7

4
10 6-10 2.2 4 4 4

5.5

7.5
14 9-14 3

5.5

5.5

7.5

7.5

9
18 13-18 4

7.5

9 9 9 11
23 17-23 5.5 11 11

11

11 15
32 24-32 7.5 15 15

15

18.5

26
JGV3-80 40 25-40 -

18.5

- - - 30
63 40-63 -

30

- - - 45
80 56-80 - 37 - - - 55

 

The enclosure protection level is: IP20;
The operating performance of the circuit breaker (see Table 3)

Type Frame rated current Inm(A) Operating cycles per hour Operation cycle times
Power ups No power Total
1 32 120 2000 10000 12000
2 80 120 2000 10000 12000

Outline and Mounting Dimension

product5


Product detail pictures:


Related Product Guide:

Reliable quality and good credit standing are our principles, which will help us at a top-ranking position. Adhering to the tenet of "quality first, customer supreme" for Factory Supply Circuit Breaker - GV2-M motor protector with overcurrent protection – JUHONG , The product will supply to all over the world, such as: Colombia, Ecuador, Mozambique, If you need any of our products, or have other items to be produced, please send us your inquiries, samples or detailed drawings. Meanwhile, aiming to develop into an international enterprise group, we look forward to receiving offers for joint ventures and other cooperative projects.
The factory technical staff gave us a lot of good advice in the cooperation process, this is very good, we are very grateful.
5 Stars By Julia from Milan - 2018.09.21 11:01
This is the first business after our company establish, products and services are very satisfying, we have a good start, we hope to cooperate continuous in the future!
5 Stars By Dawn from France - 2018.06.12 16:22
Write your message here and send it to us