Type | J3TF-9/12 | J3TF-16/22 | J3TF-32 | J3TF-45/63 | J3TF-75/85 | J3TF-110/140 | J3TF-170/205 | J3TF-250/300 | J3TF-400/475 | |
Mechanical Endurance(X106) |
10 | 10 | 10 | 8 | 8 | 8 | 8 | 8 | 8 | |
Conventional thermal current(A) |
20 | 30 | 45 | 80 | 100 | 160 | 210 | 300 | 400/550 | |
Rated insulation voltage(V) |
660 | 660 | 660 | 1000 | 1000 | 1000 | 1000 | 1000 | 1000 | |
Rated operating current(A) |
AC-3 | 9/12 | 16/22 | 32 | 45/63 | 75/85 | 110/140 | 170/205 | 250/300 | 400/475 |
AC-4 | 3.3/4.3 | 7.7/8.5 | 15.6 | 24/28 | 34/42 | 54/68 | 75/96 | 110/125 | 150 | |
Power of controllablemotor(KW) AC-3 | 380V | 4/5.5 | 7.5/11 | 15 | 22/30 | 37/45 | 55/75 | 90/110 | 132/160 | 200/250 |
660V | 5.5/7.5 | 11 | 23 | 39/55 | 67 | 100 | 156 | 235 | 375 | |
Power of controllablemotor(KW) AC-4 | 380V | 1.4/1.9 | 3.5/4 | 7.5 | 12/14 | 17/21 | 27/35 | 38/50 | 58/66 | 81 |
660V | 2.4/3.3 | 6/6.6 | 13 | 20.8/24 | 29.5/36 | 46.9/60 | 66/86 | 100/114 | 140 | |
Frequency of operation (I/h) |
AC-3 | 1000 | 750 | 750 | 1200/1000 | 1000/850 | 1000/750 | 700/500 | 700/500 | 500/420 |
AC-4 | 250 | 250 | 250 | 400/300 | 300/250 | 300/200 | 200/130 | 200/130 | 150 | |
Electrical endurance (X106) |
AC-3 | 1.2 | 1.2 | 1.2 | 1.2 | 1.2 | 1.2 | 1.2 | 1.2 | 1.2 |
AC-4 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | |
Operating voltage range of coil |
(0.8-1.1)Ue | |||||||||
Power consumption of coil |
Atracting (VA) |
10 | 10 | 12.1 | 17 | 32 | 39 | 58 | 84 | 115 |
Starting (VA) |
68 | 69 | 101 | 183 | 330 | 550 | 910 | 1430 | 2450 | |
Rated insulation voltageof auxiliary contacts(V) | 690 | 690 | 690 | 690 | 690 | 690 | 690 | 690 | 690 | 690 |
Conventional thermal currentof auxiliary contacts(A) | 10 | 10 | 10 | 10 | 10 | 10 | 10 | 10 | 10 | 10 |
Rated operating currentof auxiliary contacts(A) | AC15 380/220 |
6/10 | 6/10 | 4/6 | 4/6 | 4/6 | 4/6 | 4/6 | 4/6 | 4/6 |
DC13 220v |
0.45 | 0.45 | 0.45 | 0.45 | 0.45 | 0.45 | 0.45 | 0.45 | 0.45 | |
Rated voltage of the control coil(V) |
50HZ | 24 36 48 110 127 220 380,etc | ||||||||
60HZ | 24 110 220 440 etc |
Product detail pictures:
Related Product Guide:
Responsible excellent and fantastic credit rating standing are our principles, which will help us at a top-ranking position. Adhering towards the tenet of "quality initial, buyer supreme" for Factory source Magnetic Contactor With Overload Relay - Siemens Type AC Contactor J3TF – JUHONG , The product will supply to all over the world, such as: Johannesburg, Austria, South Korea, With the aim of "compete with good quality and develop with creativity" and the service principle of "take customers' demand as orientation", we will earnestly provide qualified products and solutions and good service for domestic and international customers.
By Page from Egypt - 2018.12.14 15:26
The customer service staff is very patient and has a positive and progressive attitude to our interest, so that we can have a comprehensive understanding of the product and finally we reached an agreement, thanks!
By Patricia from Somalia - 2017.04.28 15:45
Write your message here and send it to us