Main Parameters And Technical Performance
● The main technical performance indicators and component equipment of the starter (see Table 1);
● The starter rated control circuit voltage Us is: AC 50/60Hz, 24V, 42V, 110V, 220/230V, 240V,
380/400V, 415V, 440V, 480V, 6OOV;
● Range of action:
○ Pull-in voltage: 50 or 60H 80%Us-110% Us; 50/60Hz 85%Us~110%Us;
○ Release voltage: 20%Us-75%Us
● The operating range of the starter with thermal (overload) relay has the operating characteristics
of thermal relay;
5. The operating frequency with thermal relay is 30 times/hour;
Technical Parameters
Type |
Maximum power AC3 duty(KW) |
Rated current(A) |
Type of enclosure |
Suitable Thermal Relay(A) |
|||||
220V 230V |
380V 400V |
415V |
440V |
500V |
660V 690V |
||||
JLE1-D09 |
2.2 |
4 |
4 |
4 |
5.5 |
5.5 |
9 |
IP42 IP65 |
JLR2-D1312 JLR2-D1314 |
JLE1-D12 |
3 |
5.5 |
5.5 |
5.5 |
7.5 |
7.5 |
12 |
IP42 IP55 |
JLR2-D1316 |
JLE1-D18 |
4 |
7.5 |
9 |
9 |
10 |
10 |
18 |
IP42 IP55 |
JLR2-D1321 |
JLE1-D25 |
5.5 |
11 |
11 |
11 |
15 |
15 |
25 |
IP42 IP55 |
JLR2-D1322 JLR2-D2353 |
JLE1-D32 |
7.5 |
15 |
15 |
15 |
18.5 |
18.5 |
32 |
IP55 |
JLR2-D2355 |
JLE1-D40 |
11 |
18.5 |
22 |
22 |
22 |
30 |
40 |
IP55 |
JLR2-D3353 JLR2-D3355 |
JLE1-D50 |
15 |
22 |
25 |
30 |
30 |
33 |
50 |
IP55 |
JLR2-D3357 JLR2-D3359 |
JLE1-D65 |
18.5 |
30 |
37 |
37 |
37 |
37 |
65 |
IP55 |
JLR2-D3361 |
JLE1-D80 |
22 |
37 |
45 |
45 |
55 |
45 |
80 |
IP55 |
JLR2-D3363 JLR2-D3365 |
JLE1-D95 |
25 |
45 |
45 |
45 |
55 |
45 |
95 |
IP55 |
JLR2-D3365 |
Enclosure |
LE1-D09 and D12 |
Double insulated, protexted to IP 429(3) or to IP 659(4) |
|||||||
LE1-D18 and D25 |
Double insulated, protexted to IP 427(3) or to IP 557(4) |
||||||||
LE1-D32…D95 |
Metal, IP 55 to IP 559 |
||||||||
Control(2 pushbuttons mounted on enclosure cover) |
LE1-D09…D95 |
1 green Start button “I” 1red Stop/Reset button”O” |
|||||||
Connections |
LE1-D32…D95 |
Pre-wired power and control circuit connections |
|||||||
Standard control circuit voltages |
|||||||||
Volts |
24 |
42 |
48 |
110 |
220/230 |
230 |
240 |
380/400 |
440 |
50/60HZ |
B7 |
D7 |
E7 |
F7 |
M7 |
P7 |
U7 |
Q7 |
R |
Shape And Installation Dimensions(mm)
Product detail pictures:
Related Product Guide:
We thinks what clients think, the urgency of urgency to act from the interests of a client position of theory, allowing for greater quality, lessen processing costs, price ranges are much more reasonable, won the new and outdated shoppers the support and affirmation for Best-Selling Condensing Unit Contactor - Magnetic Starter LE1 Series – JUHONG , The product will supply to all over the world, such as: Sweden, Birmingham, Morocco, We have now a good reputation for stable quality goods, well received by customers at home and abroad. Our company would be guided by the idea of "Standing in Domestic Markets, Walking into International Markets". We sincerely hope that we could do business with car manufacturers, auto part buyers and the majority of colleagues both at home and abroad. We expect sincere cooperation and common development!
By Olive from Adelaide - 2018.06.05 13:10
We have been engaged in this industry for many years, we appreciate the work attitude and production capacity of the company, this is a reputable and professional manufacturer.
By Phoenix from Washington - 2018.08.12 12:27