With a complete scientific quality management system, good quality and good faith, we win good reputation and occupied this field for Magnetic Contactor, Air Conditioner Contactor, Electronic Timer Relay, Clients to start with! Whatever you require, we should do our utmost to aid you. We warmly welcome prospects from everywhere in the entire world to cooperate with us for mutual enhancement.
8 Year Exporter Thermal Magnetic Circuit Breaker - Motor Protector With Overload Protection JGV2 – JUHONG Detail:

Technical Characteristic

Type Rated current of trip unit In(A) Setting current adjustment range (A) Rated ultimate short-circuit breaking capacity lcu (kA), rated operating short-circuit breaking capacity lcs (kA) Arcing distance (mm)
230/240V 400/415V 440V 500V 690V
Icu Ics Icu Ics

Icu

Ics Icu Ics Icu Ics
0.16

0.1-0.16

100 100 100 100

100

100 100 100 100 100

40

0.25

0.16-0.25

100 100 100 100

100

100 100 100 100 100

40

JGV2-32 0.4

0.25-0.4

100 100 100 100

100

100 100 100 100 100

40

0.63

0.4-0.63

100 100 100 100

100

100 100 100 100 100

40

1 0.63-1 100 100 100 100

100

100 100 100 100 100

40

1.6 1-1.6 100 100 100 100

100

100 100 100 100 100

40

2.5 1.6-2.5 100 100 100 100

100

100 100 100 3 2.25

40

4 2.5-4 100 100 100 100

100

100 100 100 3 2.25

40

6.3 4-6.3 100 100 100 100

50

50 50 50 3 2.25

40

10 6-10 100 100 100 100

15

15 10 10 3 2.25

40

14 9-14 100 100 15 7.5

8

4 6 4.5 3 2.25

40

18 13-18 100 100 15 7.5

8

4 6 4.5 3 2.25

40

23 17-23 50 50 15 6

6

3 4 3 3 2.25

40

32 24-32 50 50 15 6

6

3 4 3 3 2.25

40

JGV3-80 40 25-40 - - 35 17.5 - - - - 4 2

50

63 40-63 - - 35 17.5 - - - - 4 2

50

80 56-80 - - 35 17.5 - - - - 4 2

50

 

Rated power of the three-phase motor controlled by the circuit breaker (see Table 2)

The enclosure protection level is: IP20;
The operating performance of the circuit breaker (see Table 3)

Type Frame rated current Inm(A) Operating cycles per hour Operation cycle times
Power ups No power Total
1 32 120 2000 10000 12000
2 80 120 2000 10000 12000

Outline and Mounting Dimension

product5


Product detail pictures:

8 Year Exporter Thermal Magnetic Circuit Breaker - Motor Protector With Overload Protection JGV2 – JUHONG detail pictures

8 Year Exporter Thermal Magnetic Circuit Breaker - Motor Protector With Overload Protection JGV2 – JUHONG detail pictures

8 Year Exporter Thermal Magnetic Circuit Breaker - Motor Protector With Overload Protection JGV2 – JUHONG detail pictures

8 Year Exporter Thermal Magnetic Circuit Breaker - Motor Protector With Overload Protection JGV2 – JUHONG detail pictures

8 Year Exporter Thermal Magnetic Circuit Breaker - Motor Protector With Overload Protection JGV2 – JUHONG detail pictures


Related Product Guide:

We believe in: Innovation is our soul and spirit. High-quality is our life. Consumer need to have is our God for 8 Year Exporter Thermal Magnetic Circuit Breaker - Motor Protector With Overload Protection JGV2 – JUHONG , The product will supply to all over the world, such as: Ecuador, Kyrgyzstan, San Francisco, Our company is working by the operation principle of "integrity-based, cooperation created, people oriented, win-win cooperation". We hope we can have a friendly relationship with businessman from all over the world.
  • We always believe that the details decides the company's product quality, in this respect, the company conform our requirements and the goods are meet our expectations.
    5 Stars By Georgia from Malta - 2018.02.12 14:52
    Products and services are very good, our leader is very satisfied with this procurement, it is better than we expected,
    5 Stars By Renata from Ukraine - 2017.02.14 13:19
    Write your message here and send it to us