100% Original Compact Circuit Breaker - Moulded Case Circuit Breaker JM1 – JUHONG
100% Original Compact Circuit Breaker - Moulded Case Circuit Breaker JM1 – JUHONG Detail:
Specification
Type |
Pole |
Rated current (A) |
Rated insulation voltage (V) |
Rated operation voltage (V) |
Arcing-over Distance (mm) |
Ultimate short-circuit Breaking capacity (KA) |
Service short-circuit Breaking capacity (KA) |
Operation performance |
Utilization category |
JM1-63L |
3P/4P |
6,10,16,20,25 32,40,50,63 |
660 |
380 |
0 |
25 |
18 |
1500 |
8500 |
JM1-63M |
660 |
380 |
0 |
50 |
35 |
1500 |
8500 |
||
JM1-100L |
3P/4P |
10,16,20,25,32, |
660 |
380 |
0 |
35 |
22 |
1500 |
8500 |
JM1-100M |
660 |
380 |
≤50 |
50 |
35 |
1500 |
8500 |
||
JM1-100H |
660 |
380 |
≤50 |
85 |
50 |
1000 |
7000 |
||
JM1-225L |
3P/4P |
100, 125, 160, 180, 200, 225 |
660 |
380 |
≤50 |
35 |
22 |
1000 |
7000 |
JM1-225M |
660 |
380 |
≤50 |
50 |
35 |
1000 |
7000 |
||
JM1-225H |
660 |
380 |
≤50 |
85 |
50 |
1000 |
7000 |
||
JM1-400L |
3P/4P |
225, 250, 315, 350, 400 |
660 |
380 |
≤50 |
50 |
35 |
1000 |
4000 |
JM1-400M |
660 |
380 |
≤50 |
65 |
42 |
1000 |
4000 |
||
JM1-400H |
660 |
380 |
≤50 |
65 |
42 |
1000 |
4000 |
||
JM1-630L |
3P |
400, 500, 630 |
660 |
380 |
≤100 |
50 |
35 |
1000 |
4000 |
JM1-630M |
660 |
380 |
≤100 |
65 |
42 |
1000 |
4000 |
||
JM1-630H |
660 |
380 |
≤100 |
65 |
65 |
1000 |
4000 |
||
JM1-800M |
3P |
630, 700, 800 |
660 |
380 |
≤100 |
75 |
50 |
1000 |
4000 |
JM1-800H |
660 |
380 |
≤100 |
100 |
65 |
1000 |
4000 |
||
JM1-1250M |
3P |
1000, 1250 |
660 |
380 |
≤100 |
100 |
65 |
1000 |
4000 |
JM1-1250H |
660 |
380 |
≤100 |
125 |
75 |
1000 |
4000 |
||
JM1-1600M |
3P |
1600 |
660 |
380 |
≤100 |
150 |
80 |
1000 |
4000 |
Note
1.The MCCB has L; M; H types according to their rated limit short-circuit breaking capacity.
2.The MCCB is advantageous for its compact body, high breaking capacity(some even on flying arc), short arc-casting.
3.The MCCB has function of insulation wit its mark
4.The product complies with IEC60947-2, GB14048.2. Type code & signification
5.N-P type from 4-P has 3 types: A type: N-P without current tripper(normally open);
6.B type: N-P without current tripper working together with other 3P;
7.C type: N-P without current tripper working together with other 3P;
8.No code for distribution type breakers, 2 for motor-protection type;
9.No-code for distribution type breakers, 2 for motor-protection type;
It can be divided into L (common) type, M (standard) type and H (high) type. L type with connecting current equal to relevant frame level and M type with breaking capacity equaling to their frame level according to their rated limited short short-circuit breaking capacity (l c u).
10.Normal working situation
11.Altitude 2000m and below;
12.Ambient temperature no higher than+40ºC(45ºC for watercraft)no less than-5ºC;
13.Stand moist air;
14.Stand salty&oil mildew;
15.Most gradient 22.5°;
16.Atmosphere without corrupt&electric air and no danger of explosion;
17.Without rain effect.
Product detail pictures:
Related Product Guide:
Gaining purchaser gratification is our firm's intention eternally. We will make wonderful endeavours to build new and top-quality merchandise, satisfy your exclusive needs and provide you with pre-sale, on-sale and after-sale products and services for 100% Original Compact Circuit Breaker - Moulded Case Circuit Breaker JM1 – JUHONG , The product will supply to all over the world, such as: Brazil, Costa Rica, Swaziland, We warmly welcome domestic and overseas customers to visit our company and have business talk. Our company always insists on the principle of "good quality, reasonable price, the first-class service". We have been willing to build long-term, friendly and mutually beneficial cooperation with you.
By Dinah from Montpellier - 2017.08.28 16:02
The customer service reprersentative explained very detailed, service attitude is very good, reply is very timely and comprehensive, a happy communication! We hope to have a opportunity to cooperate.
By Andrew from Muscat - 2018.06.26 19:27